PA6 VENYL SE032 - 8428 AD MAJORIS FRANCE
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | ISO 179 | NoBreak | ||
| Charpy Notched Impact Strength | ISO 179 | 30 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.6mm | UL 94 | HB | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | ISO 178 | 50.0 | MPa | |
| Bending modulus | ISO 178 | 1300 | MPa | |
| Tensile strain | Break | ISO 527-2 | 70 | % |
| tensile strength | Break | ISO 527-2 | 45.0 | MPa |
| Tensile modulus | ISO 527-2 | 1550 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 155 | °C |
| Melting temperature | ISO 3146 | 220 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 70.0 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium,23°C,50%RH | 2.7to2.9 | % | |
| Shrinkage rate | 1.0to2.0 | % | ||
| density | ISO 1183 | 1.10 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | SolutionA | IEC 60112 | PLC 0 | |
| Volume resistivity | DIN 53482 | 1E+15 | ohms·cm | |
| Surface resistivity | DIN 53482 | 1E+12 | ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.