PP Niplene F20 AGR

0
  • Properties:
    Filler
    glass fiber reinforced material
    20%
    filler by weight

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityASTMD7921.05 g/cm³
melt mass-flow rateASTMD12384.5 g/10min
Shrinkage rateASTMD9550.30到0.70 %
Shrinkage rateASTMD9550.40到1.0 %
Water absorption rateISO620.20 %
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessR-ScaleASTMD785113
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL94HB
UL flame retardant ratingUL94HB
Hot filament ignition temperatureIEC60695-2-13650 °C
Mechanical propertiesTest ConditionTest MethodTest Result
elongationBreakASTMD6383.5 %
Flexural modulusASTMD7904500 MPa
bending strengthBreakASTMD790110 MPa
tensile strengthBreakASTMD63880.0 MPa
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapASTMD25670 J/m
Impact strength of cantilever beam gapASTMD256110 J/m
Electrical performanceTest ConditionTest MethodTest Result
Surface ResistivityIEC600931E+14 ohms
Volume resistivityIEC600931E+15 ohms·cm
dielectric strengthIEC60243-160 kV/mm
IEC602502.70
Dissipation FactorIEC602500.0
Thermal performanceTest ConditionTest MethodTest Result
ASTMD648152 °C
vicatASTMD15254138 °C
ISO11359-23E-06 cm/cm/°C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.