PPO HS2000X-111 SABIC INNOVATIVE SHANGHAI
119
Form:Granules
Properties:
Glass fiber mineral reinfDimensional stabilityLow water absorption
Typical Applications:
Swimming Pool FacilitiesElectronic and Electrical ApplicationsAir conditioning accessoriesShellSmoke detector coverWater pump accessoriesIndoor applicationsOutdoor applications
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Swimming Pool Facilities | Electronic and Electrical Applications | Air conditioning accessories | Shell | Smoke detector cover | Water pump accessories | Indoor applications | Outdoor applications |
| Properties: | Glass fiber mineral reinf | Dimensional stability | Low water absorption |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| 23°C | ASTM D256 | 130 | J/m | |
| ISO 180/1A | 9.7 | kJ/m² | ||
| Suspended wall beam without notch impact strength | 23°C | ASTM D4812 | 2200 | J/m |
| Reverse notch impact | 3.20mm | ASTM D256 | 810 | J/m |
| Dart impact | 23°C,TotalEnergy | ASTM D3763 | 443 | J |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | RadiantPanelListing(UL) | UL 94 | YES | |
| 2.01mm | UL 94 | 5VA | ||
| 1.47mm | UL 94 | V-0 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| yield | ASTM D638 | 74.0 | Mpa | |
| --1 | ASTM D638 | 3650 | Mpa | |
| Yield, 100mm span | ASTM D790 | 117 | Mpa | |
| Fracture, 50.0mm span | ASTM D790 | 117 | Mpa | |
| yield | ISO 527-2 | 71.7 | Mpa | |
| crack | ASTM D638 | 60.0 | Mpa | |
| ISO 527-2 | 57.1 | Mpa | ||
| yield | ASTM D638 | 3.8 | % | |
| ISO 527-2 | 3.7 | % | ||
| crack | ASTM D638 | 8.4 | % | |
| ISO 527-2 | 11 | % | ||
| 100mm span 5 | 100mm | ASTM D790 | 3550 | Mpa |
| 50.0mm span | ASTM D790 | 3670 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| 0.45MPa, unannealed, 6.40mm | ASTM D648 | 128 | °C | |
| RTI Elec | UL 746 | 100 | °C | |
| Linear coefficient of thermal expansion | TD:-40to40°C | ASTME831 | 7.8E-05 | cm/cm/°C |
| 1.8MPa, unannealed, 100mm span | ISO 75-2/Ae | 111 | °C | |
| 0.45MPa, unannealed, 100mm span | ISO 75-2/Be | 126 | °C | |
| Linear coefficient of thermal expansion | MD:-40to40°C | ASTME831 | 7.1E-05 | cm/cm/°C |
| 1.8MPa, unannealed, 6.40mm | ASTM D648 | 116 | °C | |
| 1.8MPa, unannealed, 3.20mm | ASTM D648 | 108 | °C | |
| 0.45MPa, unannealed, 3.20mm | ASTM D648 | 117 | °C | |
| RTI Imp | UL 746 | 85.0 | °C | |
| RTI | UL 746 | 100 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Outdoor applicability | UL 746C | f1 | ||
| Shrinkage rate | MD:3.20mm | Internal Method | 0.50-0.70 | % |
| Melt Volume Flow Rate (MVR) | 300°C/5.0kg | ISO 1133 | 6.80 | cm3/10min |
| 280°C/5.0kg | ISO 1133 | 6.80 | cm3/10min | |
| melt mass-flow rate | 300°C/5.0kg | ASTM D1238 | 7.6 | g/10min |
| 280°C/5.0kg | ASTM D1238 | 7.6 | g/10min | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot wire ignition | HWI | UL 746 | PLC 0 | |
| High voltage arc tracing rate | HVTR | UL 746 | PLC 3 | |
| High arc combustion index | HAI | UL 746 | PLC 2 | |
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 2 | |
| Arc resistance | ASTM D495 | PLC6 | ||
| Dissipation factor | 1MHz | ASTM D150 | 4.4E-03 | |
| Surface resistivity | ASTM D257 | >1.0E+16 | ohms | |
| Dielectric constant | 50Hz | ASTM D150 | 2.89 | |
| Volume resistivity | ASTM D257 | 1.2E+16 | ohms·cm | |
| Dielectric constant | 60Hz | ASTM D150 | 2.89 | |
| 1MHz | ASTM D150 | 2.70 | ||
| Dielectric strength | 3.20mm,inOil | ASTM D149 | 17 | KV/mm |
| Dissipation factor | 50Hz | ASTM D150 | 0.017 | |
| 60Hz | ASTM D150 | 0.017 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.