PC 1000 SABIC INNOVATIVE US
24
Form:Granules | Grade:Injection grade
Properties:
High mobilityHigh temperature resistan
Typical Applications:
ShellElectrical applications
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Shell | Electrical applications |
| Properties: | High mobility | High temperature resistan |
Certificates
No Data...
Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| turbidity | 2540μm | ASTM D1003 | <0.80 | % |
| Refractive index | ASTM D542 | 1.586 | ||
| ISO 489 | 1.586 | |||
| transmissivity | 2540μm | ASTM D1003 | 88.0to90.0 | % |
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Dart impact | 23°C,EnergyatPeakLoad | ASTM D3763 | 65.0 | J |
| Impact strength of cantilever beam gap | 23°C | ASTM D256 | 800 | J/m |
| -30°C | ISO 180/1A | 12 | kJ/m² | |
| 23°C | ISO 180/1A | 70 | kJ/m² | |
| 23°C | ASTM D4812 | NoBreak | ||
| Suspended wall beam without notch impact strength | -30°C | ISO 180/1U | NoBreak | |
| 23°C | ISO 180/1U | NoBreak | ||
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.6mm | UL 94 | V-2 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile strain | Break | ISO 527-2/50 | >70 | % |
| elongation | Break | ASTM D638 | >70 | % |
| Tensile strain | Yield | ISO 527-2/50 | 6.0 | % |
| elongation | Yield | ASTM D638 | 6.0 | % |
| tensile strength | Yield | ISO 527-2/50 | 63.0 | Mpa |
| Yield | ASTM D638 | 63.0 | Mpa | |
| Tensile modulus | ISO 527-2/1 | 2350 | Mpa | |
| ASTM D638 | 2350 | Mpa | ||
| Bending modulus | 50.0mmSpan | ASTM D790 | 2300 | Mpa |
| ISO 178 | 2300 | Mpa | ||
| bending strength | ISO 178 | 90.0 | Mpa | |
| Yield,50.0mmSpan | ASTM D790 | 90.0 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | ISO 306/B50 | 143 | °C | |
| ASTM D152510 | 143 | °C | ||
| Hot deformation temperature | 1.8MPa,Unannealed,64.0mmSpan | ISO 75-2/Af | 127 | °C |
| 1.8MPa,Unannealed,3.20mm | ASTM D648 | 127 | °C | |
| 0.45MPa,Unannealed,64.0mmSpan | ISO 75-2/Bf | 138 | °C | |
| 0.45MPa,Unannealed,3.20mm | ASTM D648 | 138 | °C | |
| Ball Pressure Test | 125°C | IEC 60695-10-2 | Pass | |
| Linear coefficient of thermal expansion | MD:-40to95°C | ASTME831 | 7E-05 | cm/cm/°C |
| MD:23to80°C | ISO 11359-2 | 7E-05 | cm/cm/°C | |
| thermal conductivity | ASTMC177 | 0.20 | W/m/K | |
| ISO 8302 | 0.20 | W/m/K | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium,23°C | ASTM D570 | 0.35 | % |
| Saturation,23°C | ISO 62 | 0.35 | % | |
| Shrinkage rate | MD:3.20mm | Internal Method | 0.50-0.70 | % |
| MD:--2 | Internal Method | 0.50-0.70 | % | |
| Melt Volume Flow Rate (MVR) | 300°C/1.2kg | ISO 1133 | 9.50 | cm3/10min |
| melt mass-flow rate | 300°C/1.2kg | ASTM D1238 | 10 | g/10min |
| density | ISO 1183 | 1.20 | g/cm³ | |
| ASTM D792 | 1.20 | g/cm³ | ||
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric strength | 1.60mm | ASTM D149 | 27 | KV/mm |
| 1.60mm | IEC 60243-1 | 27 | KV/mm | |
| Dielectric constant | 60Hz | ASTM D150 | 3.00 | |
| 1MHz | ASTM D150 | 3.00 | ||
| Dissipation factor | 1MHz | ASTM D150 | 0.010 | |
| 60Hz | IEC 60250 | 1E-03 | ||
| 1MHz | IEC 60250 | 0.010 | ||
| Volume resistivity | ASTM D257 | >1.0E+15 | ohms·cm | |
| IEC 60093 | >1.0E+15 | ohms·cm | ||
| Relative permittivity | 60Hz | IEC 60250 | 3.00 | |
| 1MHz | IEC 60250 | 3.00 | ||
| Dissipation factor | 60Hz | ASTM D150 | 1E-03 | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Scale | ISO 2039-2 | 120 | |
| R-Scale | ASTM D785 | 120 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.