PPS FZ-6600-R1 DIC JAPAN

28

Form:Granules | Grade:Flame retardant grade

Properties:
Filler: Glass mineral
Product Description
Certificates(0)
Datasheet

Product Description

Properties:Filler: Glass mineral

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Suspended wall beam without notch impact strengthASTM D256450J/m
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating0.8mmUL 94V-0
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile modulusASTM D63819000Mpa
tensile strengthASTM D638180Mpa
elongationBreakASTM D6381.2%
Bending modulusASTM D79018000Mpa
bending strengthASTM D790250Mpa
compressive strengthASTM D695170Mpa
Poisson's ratio0.34
Friction coefficientSteel - DynamicASTM D18940.35
Friction coefficientSteel - StaticASTM D18940.35
Elongation at BreakASTM D7901.8%
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature1.8MPa,UnannealedASTM D648265°C
Linear coefficient of thermal expansionMD:-30to90°CASTM D6961.7E-05cm/cm/°C
Linear coefficient of thermal expansionTD:-30to90°CASTM D6961.7E-05cm/cm/°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Shrinkage rateMDASTM D9550.25%
Shrinkage rateTDASTM D9551.0%
Water absorption rate23°C,24hrASTM D5700.020%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Volume resistivityASTM D2571E+16ohms·cm
Dielectric strength1.60mmASTM D14916KV/mm
Dielectric constant1MHzASTM D1505.00
Dissipation factor1MHzASTM D1506E-03
Arc resistanceASTM D495180sec
Compared to the anti leakage trace indexASTM D3638PLC 2
hardnessTest ConditionTest MethodTest ResultTest Unit
Rockwell hardnessM-ScaleASTM D785100
Rockwell hardnessR-ScaleASTM D785121
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.