ABS 25H23100 A-M 4Plas
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| other | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| UL flame retardant rating | 1.60 mm | UL 94 | V-0 | |
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 30 | kJ/m² |
| 23°C | ISO 180/1A | 40 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.6mm | UL 94 | V-0 | |
| Burning wire flammability index | 2.0mm | IEC 60695-2-12 | 960 | °C |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | 23°C | ISO 527-2/5 | 2300 | MPa |
| tensile strength | Break,23°C | ISO 527-2/5 | 44.0 | MPa |
| Rockwell hardness | R-Scale | ASTM D785 | 102 | |
| Tensile modulus | 23°C | ISO 527-2/5 | 2300 | MPa |
| tensile strength | Break, 23°C | ISO 527-2/5 | 44 | MPa |
| Tensile strain | Break, 23°C | ISO 527-2/5 | 3.0 | % |
| Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 30 | kJ/m² |
| 23°C | ISO 180/1A | 40 | kJ/m² | |
| Tensile strain | Break,23°C | ISO 527-2/5 | 3.0 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8 MPa, Unannealed | ISO 75-2/A | 104 | °C |
| Vicat softening temperature | ISO 306/B | 124 | °C | |
| Hot deformation temperature | 0.45 MPa, Unannealed | ISO 75-2/B | 118 | °C |
| 0.45MPa,Unannealed | ISO 75-2/B | 118 | °C | |
| 1.8MPa,Unannealed | ISO 75-2/A | 104 | °C | |
| Vicat softening temperature | ISO 306/B | 124 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.18 | g/cm³ | |
| melt mass-flow rate | 230°C/3.8 kg | ISO 1133 | 22 | g/10 min |
| Water absorption rate | Equilibrium, 23°C, 50% RH | ISO 62 | 0.2 | % |
| density | ISO 1183 | 1.18 | g/cm³ | |
| melt mass-flow rate | 270°C/2.16kg | ISO 1133 | 22 | g/10min |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.20 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| High arc combustion index | 1.57 mm | UL 746 | PLC 4 | |
| Hot wire ignition | 1.57 mm | UL 746 | PLC 2 | sec |
| High arc combustion index | 1.57mm | UL 746 | PLC 4 | |
| Hot wire ignition | 1.57mm | UL 746 | PLC 2 | sec |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Scale | ASTM D785 | 102 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.