PBT ENH4560 BK1066 SABIC INNOVATIVE NANSHA
33
Form:Granules | Grade:Injection grade
Properties:
Flame retardantBromine freeChlorine free
Typical Applications:
Plastic bagAutomotive External Parts
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Plastic bag | Automotive External Parts |
| Properties: | Flame retardant | Bromine free | Chlorine free |
Certificates
No Data...
Technical Data Sheet
| Filling analysis | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Melt viscosity | 260°C,1500sec^-1 | ISO 11443 | 110 | Pa·s |
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| 23°C | ISO 180/1A | 9.0 | kJ/m² | |
| -30°C | ASTM D4812 | 500 | J/m | |
| 23°C | ASTM D4812 | 500 | J/m | |
| -30°C | ISO 180/1U | 37 | kJ/m² | |
| 23°C | ISO 180/1U | 37 | kJ/m² | |
| Impact strength of simply supported beam without notch | -30°C | ISO 179/2U | 35 | kJ/m² |
| 23°C | ISO 179/2U | 40 | kJ/m² | |
| -30°C | ASTM D256 | 75 | J/m | |
| 0°C | ASTM D256 | 75 | J/m | |
| 23°C | ASTM D256 | 75 | J/m | |
| -30°C | ISO 180/1A | 9.0 | kJ/m² | |
| 0°C | ISO 180/1A | 9.0 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Hot filament ignition temperature | 1.00mm | IEC 60695-2-13 | 750 | °C |
| Burning wire flammability index | 2.00mm | IEC 60695-2-12 | 960 | °C |
| UL flame retardant rating | 3.00mm | UL 94 | 5VB | |
| 0.800mm | UL 94 | V-0 | ||
| Hot filament ignition temperature | 2.00mm | IEC 60695-2-13 | 750 | °C |
| 3.00mm | IEC 60695-2-13 | 800 | °C | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| crack | ASTM D638 | 110 | Mpa | |
| yield | ISO 527-2/5 | 105 | Mpa | |
| ASTM D638 | 110 | Mpa | ||
| --1 | ASTM D638 | 11000 | Mpa | |
| Fracture bending strain | ISO 178 | 2.0 | % | |
| crack | ISO 527-2/5 | 105 | Mpa | |
| yield | ASTM D638 | 2.0 | % | |
| ISO 527-2/5 | 2.0 | % | ||
| crack | ASTM D638 | 2.0 | % | |
| ISO 527-2/5 | 2.0 | % | ||
| 50.0mm span | ASTM D790 | 9000 | Mpa | |
| --7 | ISO 178 | 10000 | Mpa | |
| --8 | ISO 178 | 170 | Mpa | |
| Yield, 50.0mm span | ASTM D790 | 150 | Mpa | |
| Fracture, 50.0mm span | ASTM D790 | 150 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| RTI | UL 746 | 140 | °C | |
| RTI Imp | UL 746 | 125 | °C | |
| 0.45MPa, unannealed, 3.20mm | ASTM D648 | 223 | °C | |
| 0.45MPa, unannealed, 64.0mm span | ISO 75-2/Bf | 225224 | °C | |
| 1.8MPa, unannealed, 3.20mm | ASTM D648 | 210 | °C | |
| 1.8MPa, unannealed, 64.0mm span of | ISO 75-2/Af | 210 | °C | |
| Ball Pressure Test | 125°C | IEC 60695-10-2 | Pass | |
| Linear coefficient of thermal expansion | MD:-40to40°C | ISO 11359-2 | 2E-05 | cm/cm/°C |
| MD:23to150°C | ISO 11359-2 | 2.5E-05 | cm/cm/°C | |
| TD:-40to40°C | ISO 11359-2 | 6.2E-05 | cm/cm/°C | |
| TD:23to150°C | ISO 11359-2 | 1.5E-04 | cm/cm/°C | |
| RTI Elec | UL 746 | 140 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Melt Volume Flow Rate (MVR) | 250°C/5.0kg | ISO 1133 | 16.0 | cm3/10min |
| melt mass-flow rate | 265°C/5.0kg | ASTM D1238 | 23 | g/10min |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| 3.20mm, inoil | ASTM D149 | 18 | KV/mm | |
| 0.800mm, in oil | IEC 60243-1 | 32 | KV/mm | |
| 1.60mm, in oil | IEC 60243-1 | 22 | KV/mm | |
| 3.20mm, in oil | IEC 60243-1 | 18 | KV/mm | |
| 1.60mm,inOil | ASTM D149 | 22 | KV/mm | |
| 0.800mm,inOil | ASTM D149 | 32 | KV/mm | |
| Volume resistivity | ASTMD257 | 1E+14 | ohms·cm | |
| Surface resistivity | IEC 60093 | >1.0E+15 | ohms | |
| Hot wire ignition | HWI | UL 746 | PLC 0 | |
| High arc combustion index | HAI | UL 746 | PLC 0 | |
| Compared to the anti leakage trace index | IEC 60112 | V | ||
| CTI | UL 746 | PLC 0 | ||
| Dissipation factor | 1MHz | ASTMD150 | 0.14 | |
| Dielectric constant | 1MHz | ASTMD150 | 3.80 | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Ball Pressure Test | H358/30 | ISO 2039-1 | 142 | Mpa |
| Rockwell hardness | R-Sale | ISO 2039-2 | 120 | |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| Filling material | ASTM D229 | 30 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.