LLDPE 7635 HANWHA KOREA
70
Form:Granules | Grade:Injection grade
Properties:
High gloss
Typical Applications:
Lighting fixturesHousehold goods
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Lighting fixtures | Household goods |
| Properties: | High gloss |
Certificates
No Data...
Technical Data Sheet
| other | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| remarks | 加工温度:180-220℃ | |||
| characteristic | 机械物性;电器特性;挤压加工性 | |||
| Other performance | Test Condition | Test Method | Test Result | Test Unit |
| gloss | 45° | ASTM D-2457 | 80 | % |
| Turbidity | ASTM D-1009 | 10 | % | |
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | ASTM D-1238 | 20 | g/10min | |
| density | ASTM D-1505 | 0.924 | g/cc | |
| Shrinkage rate | 1-3 | % | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | ASTM D-1709 | 150 | g | |
| Shore hardness | ASTM D-1706 | 53 | Shore D | |
| Elongation (break point), longitudinal/transverse | ASTM D-882 | 650/750 | % | |
| Tensile strength (breaking point) | ASTM D-638 | 112 | ||
| Tensile strength (yield point) | ASTM D-638 | 110 | ||
| elongation | Break | ASTM D-638 | 650 | % |
| tensile strength | ASTM D-1004 | 115 | kg/cm | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | ASTM D-1525 | 95 | °C | |
| Melting temperature | ASTM D-3417 | 124 | °C | |
| Low temperature brittleness temperature | ASTM D-746 | <-76 | °C | |
| Vicat softening temperature | ASTM D1525/ISO R306 | 95 | ℃(℉) | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792/ISO 1183 | 0.924 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.