Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ISO 1183 | 1.16 g/cm³ | |
Shrinkage rate | ISO 294-4 | 1.4 % | |
ISO 294-4 | 1.2 % | ||
Water absorption rate | ISO 62 | 0.80 % | |
ISO 62 | 2.3 % |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | V-0 | |
Burning wire flammability index | IEC 60695-2-12 | 960 °C | |
IEC 60695-2-12 | 960 °C | ||
IEC 60695-2-12 | 960 °C | ||
IEC 60695-2-12 | 960 °C | ||
Hot filament ignition temperature | IEC 60695-2-13 | 875 °C | |
IEC 60695-2-13 | 875 °C | ||
IEC 60695-2-13 | 775 °C | ||
IEC 60695-2-13 | 725 °C | ||
Limiting Oxygen Index | ISO 4589-2 | 29 % | |
UL flame retardant rating | UL 94 | V-0 | |
UL 94 | V-0 | ||
UL 94 | V-0 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
bending strength | ISO 178 | 92.0 MPa | |
Poisson's ratio | ISO 527-2 | 0.40 | |
tensile strength | ISO 527-2 | 75.0 MPa | |
Tensile strain | ISO 527-2 | 5.5 % | |
Tensile modulus | ISO 527-2 | 5000 MPa | |
Tensile strain | ISO 527-2 | 25 % | |
Flexural modulus | ISO 178 | 3200 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Charpy Notched Impact Strength | ISO 179/1eA | 5.4 kJ/m² | |
ISO 179/1eA | 5.4 kJ/m² | ||
Impact strength of simply supported beam without notch | ISO 179/1eU | NoBreak | |
ISO 179/1eU | NoBreak | ||
Impact strength of cantilever beam gap | ISO 180 | 6.0 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Volume resistivity | IEC 60093 | 1E+11 ohms·cm | |
dielectric strength | IEC 60243 | 13 kV/mm | |
arc resistance | ASTM D495 | PLC 5 | |
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 0 | |
High arc combustion index (HAI) | UL 746 | PLC 0 | |
UL 746 | PLC 0 | ||
UL 746 | PLC 0 | ||
UL 746 | PLC 0 | ||
High Voltage Arc Traceability Rate (HVTR) | UL 746 | PLC 1 | |
Hot wire ignition (HWI) | UL 746 | PLC 4 | |
UL 746 | PLC 4 | ||
UL 746 | PLC 4 | ||
UL 746 | PLC 3 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
RTI Str | UL 746 | 100 °C | |
UL 746 | 100 °C | ||
UL 746 | 100 °C | ||
UL 746 | 110 °C | ||
Hot deformation temperature (HDT) | ISO 75-2/B | 225 °C | |
ISO 75-2/A | 65.0 °C | ||
melting temperature | ISO 11357-3 | 244 °C | |
ISO 11359-2 | 1.1E-04 cm/cm/°C | ||
ISO 11359-2 | 1.1E-04 cm/cm/°C | ||
RTI Elec | UL 746 | 130 °C | |
UL 746 | 130 °C | ||
UL 746 | 130 °C | ||
UL 746 | 130 °C | ||
RTI Imp | UL 746 | 65.0 °C | |
UL 746 | 65.0 °C | ||
UL 746 | 85.0 °C | ||
UL 746 | 85.0 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.