PMMA V 920T France Arkema Altuglas
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Refractive index | ISO 489 | 1.490 | ||
| transmissivity | ASTM D1003 | 92.0 | % | |
| turbidity | ASTM D1003 | 0.50 | % | |
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Charpy Notched Impact Strength | 23°C | ISO 179/2C | 2.0 | kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/2U | 11 | kJ/m² |
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 1.8 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL 94 | HB | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Yield,23°C | ISO 527-2 | 70.0 | MPa |
| Tensile strain | Break,23°C | ISO 527-2 | 6.0 | % |
| Bending modulus | 23°C | ISO 178 | 3300 | MPa |
| bending strength | 23°C | ISO 178 | 103 | MPa |
| Compressive stress | 23°C | ISO 604 | 110 | MPa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 95.0 | °C |
| Vicat softening temperature | ISO 306/B | 103 | °C | |
| Linear coefficient of thermal expansion | MD:-30to23°C | ASTM D696 | 6.5E-05 | cm/cm/°C |
| specific heat | 2090 | J/kg/°C | ||
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 100 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | 230°C/3.8kg | ISO 1133 | 6.0 | g/10min |
| Shrinkage rate | MD | ASTM D955 | 0.20to0.60 | % |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.30 | % |
| density | ISO 1183 | 1.18 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | ASTM D257 | >1.0E+14 | ohms | |
| Volume resistivity | ASTM D257 | >1.0E+15 | ohms·cm | |
| Dielectric strength | ASTM D149 | 20 | kV/mm | |
| Dissipation factor | 1MHz | ASTM D150 | 0.040 | |
| Dielectric constant | 60Hz | ASTM D150 | 3.70 | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | M-Scale | ASTM D785 | 96 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.