Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ASTMD570 | 1.1 % |
Shrinkage rate | | ASTMD955 | 0.30 % |
density | | ASTMD792 | 1.38 g/cm³ |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | R-Scale | ASTMD785 | 121 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL94 | HB |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | Break | ASTMD638 | 190 MPa |
elongation | Break | ASTMD638 | 3.5 % |
Flexural modulus | | ASTMD790 | 8960 MPa |
bending strength | | ASTMD790 | 301 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTMD256 | 120 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Volume resistivity | | ASTMD257 | 1E+15 ohms·cm |
dielectric strength | | ASTMD149 | 17 kV/mm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ASTMD648 | 216 °C |
| | ASTMD648 | 210 °C |
melting temperature | | | 220 °C |
| | ASTMD696 | 3.8E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.