TPU-Est/eth DP R 9918 geba Kunststoffcompounds GmbH
0
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Charpy Notched Impact Strength | -30°C | ISO 179/1eA | 22 kJ/m² |
| 23°C | ISO 179/1eA | 45 kJ/m² | |
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 无断裂 |
| 23°C | ISO 179/1eU | 无断裂 |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Bending modulus | 23°C | ISO 178 | 1800 MPa |
| bending strength | -30°C | ISO 178 | 118 MPa |
| 23°C | ISO 178 | 54.0 MPa | |
| tensile strength | ISO 527-2/200 | 59.0 MPa | |
| Tensile strain | Break | ISO 527-2/200 | 17 % |
| Bending modulus | -30°C | ISO 178 | 3000 MPa |
| Wear resistance | ISO 4649 | 80 mm³ |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 167 °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 126 °C | |
| Vicat softening temperature | ISO 306/B50 | 92.0 °C | |
| Linear coefficient of thermal expansion | MD | DIN 53752 | 1E-05 cm/cm/°C |
| TD | DIN 53752 | 1.1E-04 cm/cm/°C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| density | ISO 1183/A | 1.29 g/cm³ | |
| Shrinkage rate | TD | 0.32 % | |
| MD | 0.10 % |
| hardness | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shore hardness | ShoreD | ISO 868 | 64 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.