POM Homopolymer MAJORIS POM GRIS 8109 AD MAJORIS FRANCE
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 5.5 | kJ/m² |
| 23°C | ISO 180/1A | 5.5 | kJ/m² | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile strain | Yield | ISO 527-2/50 | 9.0 | % |
| Bending modulus | ISO 178 | 2700 | MPa | |
| bending strength | 3.5%Strain | ISO 178 | 67.0 | MPa |
| Tensile modulus | ISO 527-2 | 2800 | MPa | |
| tensile strength | Yield | ISO 527-2/50 | 32.0 | MPa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 104 | °C |
| Melting temperature | ISO 3146 | 166 | °C | |
| Linear coefficient of thermal expansion | MD:23to80°C | DIN 52328 | 1.2E-04 | cm/cm/°C |
| Vicat softening temperature | ISO 306/B50 | 151 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.41 | g/cm³ | |
| melt mass-flow rate | 190°C/2.16kg | ISO 1133 | 10 | g/10min |
| Water absorption rate | 23°C,24hr | ISO 62 | 0.65 | % |
| Equilibrium,23°C,50%RH | ISO 62 | 0.20 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric strength | IEC 60243-1 | 35 | kV/mm | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Ball Pressure Test | ISO 2039-1 | 144 | MPa |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.