Share
Add to compare

PA6 BKV140H2.0 900051 LANXESS GERMANY

39

Form:Granules | Grade:Injection grade

Product Description
Certificates(1)
Datasheet

Product Description

Certificates

UL
UL

Technical Data Sheet

otherTest ConditionTest MethodTest ResultTest Unit
characteristic抗冲击 热稳定性
impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of simply supported beam without notch-30°CISO 179/1eU100kJ/m²
Impact strength of simply supported beam without notch23°CISO 179/1eU110kJ/m²
Suspended wall beam without notch impact strength-30°CISO 180/1U90kJ/m²
Suspended wall beam without notch impact strength23°CISO 180/1U90kJ/m²
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile modulusASTM D638/ISO 52711200kg/cm²(MPa)[Lb/in²]
tensile strengthASTM D638/ISO 527174kg/cm²(MPa)[Lb/in²]
Bending modulusASTM D790/ISO 17810400kg/cm²(MPa)[Lb/in²]
bending strengthASTM D790/ISO 178280kg/cm²(MPa)[Lb/in²]
bending strengthFlexuralStrainatFlexuralStrength5(23°C)4.2%
Tensile modulus23°CISO 527-2/112000Mpa
tensile strengthBreak,23°CISO 527-2/5185Mpa
Tensile strainBreak,23°CISO 527-2/53.4%
Bending modulus23°CISO 178/A11000Mpa
bending strength3.5%StrainISO 178/A280Mpa
bending strength23°CISO 178290Mpa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Combustibility (rate)UL 94HB
Vicat softening temperatureASTM D1525/ISO R306200℃(℉)
Hot deformation temperature0.45MPa,UnannealedISO 75-2/B217°C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A201°C
Melting temperatureISO 11357-3220°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
densityASTM D792/ISO 11831.46
Shrinkage rateTD:280°C,2.00mm2ISO 294-40.75%
Shrinkage rateTD:120°C,2hr,2.00mm3ISO 294-40.090%
Shrinkage rateMD:280°C,2.00mm2ISO 294-40.21%
Shrinkage rateMD:120°C,2hr,2.00mm3ISO 294-40.070%
Supplementary InformationTest ConditionTest MethodTest ResultTest Unit
ISO ShortcutISO 1874PA6HI.GR.14-120.GF40
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.