PC 201-22 STYRON US
7
Form:Granules | Grade:Injection grade
Properties:
High mobility
Typical Applications:
Food containers
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Food containers |
| Properties: | High mobility |
Certificates
No Data...
Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Refractive index | ASTM D542 | 1.586 | ||
| ISO 489 | 1.586 | |||
| transmissivity | ASTM D1003 | 89.0 | % | |
| turbidity | ASTM D1003 | 1.0 | % | |
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | ASTM D1822 | 378 | kJ/m² | |
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA2 | 70.0 | kJ/m² |
| -30°C | ISO 179/1eA2 | 11.0 | kJ/m² | |
| 23°C | ISO 179/1eU2 | NoBreak | ||
| -30°C | ISO 179/1eU2 | NoBreak | ||
| Impact strength of cantilever beam gap | 23°C | ASTM D256 | 750 | J/m |
| 23°C | ISO 180/A | 74 | kJ/m² | |
| 23°C | ASTM D256 | NoBreak | ||
| Suspended wall beam without notch impact strength | 23°C | ISO 180 | NoBreak | |
| InstrumentedDartImpact | 23°C,TotalEnergy | ASTM D3763 | 72.3 | J |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.6mm | UL 94 | HB | |
| 3.2mm | UL 94 | HB | ||
| BurningBehav.at1.6mmnom.thickn | 1.60mm,UL | ISO 12102 | HB | |
| Burning Behav.atthicknessh | 3.20mm,UL | ISO 12102 | HB | |
| Extreme Oxygen Index | ISO 4589-2 | 26 | % | |
| Limiting Oxygen Index (LOI) | ISO 4589-22 | 26 | % | |
| Average degree of combustion | ASTM D635 | 3 | CM | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Taber abraser | ASTM D1044 | 45 | % | |
| tensile strength | Break | ASTM D638 | 65.5 | Mpa |
| Break | ISO 527-2/50 | 66.0 | Mpa | |
| Tensile strain | Yield | ISO 527-22 | 6.0 | % |
| elongation | Break | ASTM D638 | 120 | % |
| Tensile strain | Break | ISO 527-2/50 | 120 | % |
| Nominal fracture strain | ISO 527-22 | >50 | % | |
| Bending modulus | ASTM D790 | 2410 | Mpa | |
| ISO 178 | 2400 | Mpa | ||
| bending strength | ASTM D790 | 96.5 | Mpa | |
| ISO 178 | 97.0 | Mpa | ||
| Tensile modulus | ASTM D638 | 2340 | Mpa | |
| ISO 527-2/50 | 2300 | Mpa | ||
| ISO 527-22 | 2300 | Mpa | ||
| tensile strength | Yield | ASTM D638 | 60.0 | Mpa |
| Yield | ISO 527-2/50 | 60.0 | Mpa | |
| Yield | ISO 527-22 | 60.0 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 139 | °C |
| 0.45MPa,Annealed | ASTM D648 | 142 | °C | |
| 0.45MPa,Annealed | ISO 75-2/B | 142 | °C | |
| 0.45MPa | ISO 75-22 | 142 | °C | |
| 1.8MPa,Unannealed | ASTM D648 | 126 | °C | |
| 1.8MPa,Annealed | ASTM D648 | 139 | °C | |
| 1.8MPa,Annealed | ISO 75-2/A | 126 | °C | |
| 1.8MPa | ISO 75-22 | 128 | °C | |
| Vicat softening temperature | ASTM D15257 | 147 | °C | |
| ISO 306/B50 | 147 | °C | ||
| 50N | ISO 3062 | 147 | °C | |
| Ball pressure temperature | IEC 60335-1 | 125 | °C | |
| Linear coefficient of thermal expansion | MD:-40to82°C | ASTM D696 | 6.8E-05 | cm/cm/°C |
| MD | ISO 11359-22 | 7E-05 | cm/cm/°C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792 | 1.20 | g/cm³ | |
| ISO 1183/A | 1.20 | g/cm³ | ||
| ISO 11832 | 1200 | kg/m3 | ||
| melt mass-flow rate | 300°C/1.2kg | ASTM D1238 | 22 | g/10min |
| 300°C/1.2kg | ISO 1133 | 22 | g/10min | |
| Melt Volume Flow Rate (MVR) | 300°C/1.2kg | ISO 11332 | 18.0 | cm3/10min |
| Shrinkage rate | MD | ASTM D955 | 0.50-0.70 | % |
| MD | ISO 294-4 | 0.50-0.70 | % | |
| Water absorption rate | 23°C,24hr | ASTM D570 | 0.15 | % |
| 23°C,24hr | ISO 62 | 0.15 | % | |
| Equilibrium,23°C,50%RH | ASTM D570 | 0.32 | % | |
| Equilibrium,23°C,50%RH | ISO 62 | 0.32 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric strength | IEC 60243-1 | 17 | KV/mm | |
| IEC 60243-12 | 17 | KV/mm | ||
| Dielectric constant | 60Hz | ASTM D150 | 3.00 | |
| 1MHz | ASTM D150 | 3.00 | ||
| Relative permittivity | 100Hz | IEC 602502 | 3.00 | |
| 1MHz | IEC 602502 | 3.00 | ||
| Dissipation factor | 50Hz | ASTM D150 | 1E-03 | |
| 1MHz | ASTM D150 | 2E-03 | ||
| 100Hz | IEC 602502 | 1E-03 | ||
| 1MHz | IEC 602502 | 2E-03 | ||
| Compared to the anti leakage trace index | 2.00mm,SolutionA | IEC 60112 | PLC 2 | |
| Volume resistivity | ASTM D257 | 2E+17 | ohms·cm | |
| IEC 600932 | >1.0E+13 | ohms·m | ||
| Dielectric strength | ASTM D149 | 17 | KV/mm | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | M-Sale | ASTM D785 | 72 | |
| R-Sale | ASTM D785 | 118 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.