Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTMD792 | 1.37 g/cm³ |
Water absorption rate | | ASTMD570 | 14 % |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL94 | HB |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTMD256 | 67 J/m |
Impact strength of cantilever beam gap | | ASTMD256 | 61 J/m |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | | ASTMD638 | 110 MPa |
tensile strength | Across Flow | ASTMD638 | 58.6 MPa |
bending strength | | ASTMD790 | 154 MPa |
bending strength | | ASTMD790 | 105 MPa |
compressive strength | | ASTMD695 | 96.5 MPa |
compressive strength | | ASTMD695 | 80.7 MPa |
compressive strength | | ASTMD695 | >310 MPa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
High arc combustion index (HAI) | | UL746 | >200 |
High Voltage Arc Traceability Rate (HVTR) | | UL746 | 1.40 mm/min |
Hot wire ignition (HWI) | | UL746 | 30 sec |
DielectricBreakdown | | ASTMD149 | 60000 V |
dielectric strength | | ASTMD149 | 12 kV/mm |
dielectric constant | | ASTMD150 | 6.81 |
dielectric constant | | ASTMD150 | 5.93 |
Dissipation Factor | | ASTMD150 | 0.054 |
Dissipation Factor | | ASTMD150 | 0.052 |
arc resistance | | ASTMD495 | 128 sec |
Compared to the Leakage Tracking Index (CTI) | | UL746 | >500 V |
Thermal performance | Test Condition | Test Method | Test Result |
---|
RTI Elec | | UL746 | 90.0 °C |
RTI | | UL746 | 90.0 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.