PA46 TW241F3 DSM HOLAND
135
Form:Granules | Grade:Injection grade
Properties:
Thermal stabilityLubricity
Typical Applications:
Automotive ApplicationsHome appliance components
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive Applications | Home appliance components |
| Properties: | Thermal stability | Lubricity |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 50 | kJ/m² |
| -30°C | ISO 179/1eU | 45 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Flammability level | UL 94 | HB | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | ISO 178 | 5800 | Mpa | |
| Tensile strain | Break, 200°C | ISO 527-2 | 12 | % |
| Break, 180°C | ISO 527-2 | 12 | % | |
| Break, 160°C | ISO 527-2 | 12 | % | |
| Break, 120°C | ISO 527-2 | 12 | % | |
| Break | ISO 527-2 | 4.0 | % | |
| Tensile modulus | 160°C | ISO 527-2 | 2650 | Mpa |
| 120°C | ISO 527-2 | 3000 | Mpa | |
| -- | ISO 527-2 | 6100 | Mpa | |
| tensile strength | Break, 200°C | ISO 527-2 | 65.0 | Mpa |
| Break, 180°C | ISO 527-2 | 70.0 | Mpa | |
| Break, 160°C | ISO 527-2 | 75.0 | Mpa | |
| Break, 120°C | ISO 527-2 | 85.0 | Mpa | |
| Break | ISO 527-2 | 140 | Mpa | |
| Tensile modulus | 200°C | ISO 527-2 | 2350 | Mpa |
| 180°C | ISO 527-2 | 2500 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| RTI Elec | 0.75 mm | UL 746 | 65.0 | °C |
| Linear coefficient of thermal expansion | Across Flow | ISO 11359-2 | 8.0E-5 | cm/cm/°C |
| Flow | ISO 11359-2 | 5.0E-5 | cm/cm/°C | |
| Melting temperature | ISO 11357-3 | 295 | °C | |
| Hot deformation temperature | 1.8 MPa, Unannealed | ISO 75-2/A | 275 | °C |
| 0.45 MPa, Unannealed | ISO 75-2/B | 290 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium, 23°C, 50% RH | ISO 62 | 3.2 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.