physical property Test ConditionTest MethodTest Result
Water absorption rateASTMD5700.050 %
densityASTMD7921.74 g/cm³
Apparent densityASTMD18950.93 g/cm³
Shrinkage rateASTMD9550.43 %
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessM-ScaleASTMD785110
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusASTMD63815400 MPa
tensile strengthASTMD63843.0 MPa
elongationBreakASTMD6380.30 %
Flexural modulusASTMD79012700 MPa
bending strengthASTMD79072.4 MPa
compressive strengthASTMD695144 MPa
Impact resistanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthASTMD25614.4 J/m
Impact strength of cantilever beam gapASTMD25616 J/m
Thermal performanceTest ConditionTest MethodTest Result
ASTMD648180 °C
Continuous use temperatureASTMD794257 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.