PA46 LDS85 BK DSM HOLAND
41
Form:Granules
Properties:
Glass fiber reinforcedThermal stability
Typical Applications:
Home appliance componentsElectronic and electrical components
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Home appliance components | Electronic and electrical components |
| Properties: | Glass fiber reinforced | Thermal stability |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 27 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Flammability level | UL 94 | HB | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2 | 10000 | Mpa | |
| tensile strength | Break | ISO 527-2 | 125 | Mpa |
| Tensile strain | Break | ISO 527-2 | 2.2 | % |
| Bending modulus | ISO 178 | 8400 | Mpa | |
| bending strength | ISO 178 | 190 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45 MPa, Unannealed | ISO 75-2/B | 315 | °C |
| 1.8 MPa, Unannealed | ISO 75-2/A | 285 | °C | |
| Glass transition temperature | ISO 11357-2 | 125 | °C | |
| Melting temperature | ISO 11357-3 | 325 | °C | |
| Linear coefficient of thermal expansion | Flow | ISO 11359-2 | 1.8E-5 | cm/cm/°C |
| Across Flow | ISO 11359-2 | 6.0E-5 | cm/cm/°C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Spiral flow length | 9.00 | CM | ||
| Shrinkage rate | 横向Flow | ISO 294-4 | 1.3 | % |
| Flow | ISO 294-4 | 0.33 | % | |
| Water absorption rate | 24 hr, 23°C | ISO 62 | 0.28 | % |
| Equilibrium, 23°C, 50% RH | ISO 62 | 1.5 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Relative permittivity | 5.00 GHz | IEC 60250 | 3.73 | |
| Dissipation factor | 5.00 GHz | IEC 60250 | 0.014 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.