Technical Data Sheet
physical property | Test Condition | Test Method | Test Result | Unit |
---|
Melt Volume-Flow Rate (MVR) | 220℃/2.16 kg | ISO 1133 | 11.0 | cm3/10min |
Shrinkage rate | MD,23℃ | ISO 294-4 | 0.60 到 0.80 | % |
Shrinkage rate | MD2.0mm | ISO294-4 | 0.70 | % |
Melt mass flow rate | 220℃/10Kg | ISO1133 | 11.00 | cm3/10min |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell hardness | | ISO2039-2 | 107 | R |
Rockwell hardness | 23℃ | ISO 2039-2 | 107 | R 计秤 |
Tensile modulus | 23℃ | ISO 527-2 | 2350 | Mpa |
tensile strength | 23℃ | ISO 527-2 | 47.0 | Mpa |
Bending modulus | 23℃ | ISO 178 | 2600 | Mpa |
bending strength | 23℃ | ISO 178 | 76.0 | Mpa |
Impact strength of simply supported beam gap | -30℃ | ISO 179 | 5.0 | kJ/m² |
tensile strength | 23°C | ISO527-2 | 47 | Mpa |
Tensile modulus | 23°C | ISO527-2 | 2350 | Mpa |
bending strength | 23°C | ISO178 | 76 | Mpa |
Bending modulus | 23°C | ISO178 | 2600 | Mpa |
Impact strength of simply supported beam gap | 23°C | ISO179/1eA | 13 | kJ/m² |
Impact strength of simply supported beam gap | -30°C | ISO179/1eA | 5.0 | kJ/m² |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|
Hot deformation temperature | 1.80MPa退火 | ISO75-2/Af | 82 | °C |
Linear coefficient of thermal expansion | MD | ISO11359-2 | 9E-05 | cm/cm/°C |
Hot deformation temperature | 1.80MPa,未退火 | ISO 75-2/Af | 82.0 | °C |
Linear expansion coefficient | 流动 | ISO 11359-2 | 0.000090 | cm/cm/℃ |
Flame retardant grade | 1.50mm | UL 94 | HB | |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Volume resistance | | IEC60093 | 1E+15 | Ω.cm |
Insulation strength | | IEC60243-1 | 32 | KV/mm |
flammability | Test Condition | Test Method | Test Result | Unit |
---|
Fire rating | | UL-94 | 1.50mm | HB |
Fire rating | | UL-94 | 3.00mm | HB |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.