PA66 A205F BK SOLVAY FRANCE
47
Form:Granules | Grade:Injection grade
Properties:
Good liquidityOrdinary useAdding lubrication
Typical Applications:
Suitable for long and thin walled componentsSuch as ties etc
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Suitable for long and thin walled components | Such as ties | etc |
| Properties: | Good liquidity | Ordinary use | Adding lubrication |
Certificates
No Data...
Technical Data Sheet
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Water absorption rate | 23℃,24hr | ISO 62 | 1.2 | % |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | RH0/RH50 | ISO 180/1A(93) | 5/12 | kJ/m² |
| Tensile modulus | RH0/RH50 | ISO 527-2 | 3200/1600 | Mpa |
| Elongation at Break | ISO 527-2 | 85/50 | Mpa | |
| Impact strength of simply supported beam without notch | ISO 179/1eU | NB/NB | kJ/m² | |
| Elongation at Break | RH0/RH50 | ISO 527-2 | 20/>50 | % |
| Charpy Notched Impact Strength | RH0/RH50 | ISO 179/1eA | 5/15 | kJ/m² |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | ISO 3146-C | 260 | °C | |
| Linear coefficient of thermal expansion | 23-85℃ | ASTM E-831 | 7 | 10-5·K-1 |
| Hot deformation temperature | 1.80MPa | ISO 75-2 | 75 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Oxygen index | ISO 4589 | 29 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | IEC 93 | 1015/1013 | Ω.cm | |
| Dielectric loss | RH0/RH50,1MHz | IEC 250 | 0.03/0.08 | |
| Dielectric constant | RH0/RH50,1MHz | IEC 250 | 2.9/3.2 | |
| Anti arc track KC | RH0/RH50 | IEC 112 | 600 | V |
| Dielectric strength | RH0/RH50 | IEC 243 | 27/26 | KV/mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.