PBT GP1000 LG GUANGZHOU
36
Form:Granules
Typical Applications:
Application in the automotive field
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Application in the automotive field |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C,6.40mm | ASTM D256 | 51 | J/m |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.71mm | UL 94 | HB | |
| 1.5mm | UL 94 | HB | ||
| 3.3mm | UL 94 | HB | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | 3.20mm | ASTM D790 | 1860 | Mpa |
| bending strength | Yield,3.20mm | ASTM D790 | 65.7 | Mpa |
| tensile strength | Yield,3.20mm | ASTM D638 | 46.1 | Mpa |
| elongation | Break,3.20mm | ASTM D638 | >100 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed,6.40mm | ASTM D648 | 57.0 | °C |
| RTI | UL 746 | 140 | °C | |
| RTI Imp | UL 746 | 130 | °C | |
| Melting temperature | ASTM D3418 | 223 | °C | |
| RTI Elec | UL 746 | 140 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 23°C,24hr | ASTM D570 | 0.080 | % |
| Shrinkage rate | MD | ASTM D955 | 1.2-2.0 | % |
| melt mass-flow rate | 250°C/2.16kg | ASTM D1238 | 34 | g/10min |
| density | ASTM D792 | 1.29 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric strength | 1.00mm | ASTM D149 | 23 | KV/mm |
| Arc resistance | ASTM D495 | PLC 5 | ||
| Compared to the anti leakage trace index | CTI)5 | UL 746 | PLC 0 | |
| SolutionA | IEC 60112 | PLC 0 | ||
| Volume resistivity | ASTM D257 | 1E+17 | ohms·cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.