PP INSTRUC PPGF30CC USA Infinity LTL
Properties:
Filler glass fiber reinforced material 30% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass fiber reinforced material | 30% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | ASTM D256 | 96 | J/m | |
| ASTM D256 | 530to640 | J/m | ||
| ASTM D256 | 530to640 | J/m | ||
| ASTM D256 | 96 | J/m | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Break | ASTM D638 | 93.1 | MPa |
| elongation | Break | ASTM D638 | 4.0to5.0 | % |
| Bending modulus | ASTM D790 | 5520 | MPa | |
| bending strength | ASTM D790 | 124 | MPa | |
| Bending modulus | ASTM D790 | 5520 | MPa | |
| bending strength | ASTM D790 | 124 | MPa | |
| tensile strength | Break | ASTM D638 | 93.1 | MPa |
| elongation | Break | ASTM D638 | 4.0to5.0 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 154 | °C |
| 1.8MPa,Unannealed | ASTM D648 | 154 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | MD:3.18mm | ASTM D955 | 0.20to0.40 | % |
| Water absorption rate | Equilibrium | ASTM D570 | 0.030 | % |
| density | ASTM D792 | 1.13 | g/cm³ | |
| ASTM D792 | 1.13 | g/cm³ | ||
| Shrinkage rate | MD:3.18mm | ASTM D955 | 0.20to0.40 | % |
| Water absorption rate | Equilibrium | ASTM D570 | 0.030 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | ASTM D257 | >1.0E+17 | ohms | |
| ASTM D257 | >1.0E+17 | ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.