TPE ProvaMed® TPE 1158 ACTEGA GmbH
0
- Usages:Medical and nursing supplies
Technical Data Sheet
| elastomer | Test Condition | Test Method | Test Result |
|---|---|---|---|
| tensile strength | 100%Strain | DIN 53504 | 2.00 MPa |
| Yield | DIN 53504 | 5.40 MPa | |
| elongation | Break | DIN 53504 | 1100 % |
| Permanent compression deformation | 23°C,22hr | ISO 815 | 23 % |
| 70°C,22hr | ISO 815 | 89 % |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Melting temperature | DSC | 151 °C | |
| Glass transition temperature | DSC | -57.0 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| density | ISO 1183 | 1.00 g/cm³ | |
| melt mass-flow rate | 190°C/5.0kg | ISO 1133 | 35 g/10min |
| hardness | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shore hardness | ShoreA,5Sec | ASTM D2240 | 58 |
| ShoreD,5Sec | ASTM D2240 | 12 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.