Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.61 g/cm³ |
Shrinkage rate | | ASTM D955 | 0.35 % |
flammability | Test Condition | Test Method | Test Result |
---|
Smoke density | | ASTME662 | 30 Ds |
UL flame retardant rating | | UL 94 | V-0 |
Limiting Oxygen Index | | ASTM D2863 | 41 % |
Smoke density | | ASTME662 | 30 Ds |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
elongation | Break | ASTM D638 | 4.3 % |
Flexural modulus | | ASTM D790 | 8200 MPa |
bending strength | | ASTM D790 | 138 MPa |
Tensile modulus | | ASTM D638 | 15800 MPa |
tensile strength | Break | ASTM D638 | 103 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ASTM D6110 | 45.0 J/m |
Impact strength of cantilever beam gap | | ASTM D256 | 60 J/m |
Suspended wall beam without notch impact strength | | ASTM D256 | 210 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | 内部方法 | 0.45 ohms |
Volume resistivity | | 内部方法 | 0.38 ohms·cm |
Electromagnetic shielding effectiveness (EMI) | | IEEE299 | 80 dB |
Electromagnetic shielding effectiveness (EMI) | | ASTM D4935 | 72 dB |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTM D648 | 184 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.