PPA UL-4020 BK SABIC INNOVATIVE US
105
Form:Granules | Grade:Injection grade
Properties:
Thermal stabilityCarbon fiber reinforced
Typical Applications:
Mechanical partsconsumer goods
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Mechanical parts | consumer goods |
| Properties: | Thermal stability | Carbon fiber reinforced |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 2.7 | kJ/m² |
| Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 27 | kJ/m² |
| Dart impact | 23°C,TotalEnergy | ASTM D3763 | 2.80 | J |
| Multi axis Instrumented Impact Energy | ISO 6603-2 | 0.500 | J | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Friction coefficient | Static | ASTM D3702Modified | 0.17 | |
| Wear factor | Ring | ASTM D3702Modified | -0.100 | 10^-10in^5-min/ft-lb-hr |
| Washer | ASTM D3702Modified | 20.0 | 10^-10in^5-min/ft-lb-hr | |
| tensile strength | Break | ASTM D638 | 60.0 | Mpa |
| Break | ISO 527-2/5 | 60.0 | Mpa | |
| elongation | Yield | ASTM D638 | 2.2 | % |
| Tensile strain | Yield | ISO 527-2/5 | 2.2 | % |
| elongation | Break | ASTM D638 | 2.2 | % |
| Tensile strain | Break | ISO 527-2/5 | 2.2 | % |
| Bending modulus | 50.0mmSpan | ASTM D790 | 2980 | Mpa |
| bending strength | Yield,50.0mmSpan | ASTM D790 | 105 | Mpa |
| Break,50.0mmSpan | ASTM D790 | 105 | Mpa | |
| Friction coefficient | Dynamic | ASTM D3702Modified | 0.27 | |
| Tensile modulus | ASTM D638 | 3170 | Mpa | |
| ISO 527-2/1 | 3220 | Mpa | ||
| tensile strength | Yield | ASTM D638 | 60.0 | Mpa |
| Yield | ISO 527-2/5 | 58.0 | Mpa | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | MD:24hr | ASTM D955 | 0.90-2.0 | % |
| TD:24hr | ASTM D955 | 0.70-0.90 | % | |
| Water absorption rate | 24hr,50%RH | ASTM D570 | 0.47 | % |
| Equilibrium,23°C,50%RH | ISO 62 | 0.73 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.