PA66 HTN53G50HSLRHF BK618A DUPONT USA
75
Form:Granules | Grade:Injection grade
Properties:
Flame retardantThermal stabilityHigh temperature resistanGlass fiber reinforced
Typical Applications:
Food containers
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Food containers |
| Properties: | Flame retardant | Thermal stability | High temperature resistan | Glass fiber reinforced |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 95 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| FMVSS flammability | FMVSS302 | B | ||
| Extreme Oxygen Index | ISO 4589-2 | 27 | % | |
| UL flame retardant rating | 1.5mm | IEC 60695-11-10,-20 | HB | |
| 0.75mm | IEC 60695-11-10,-20 | HB | ||
| 1.5mm | UL 94 | HB | ||
| 0.75mm | UL 94 | HB | ||
| Burning rate | 1.00mm | ISO 3795 | 25 | mm/min |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Poisson's ratio | ISO 527 | 0.38 | ||
| Bending modulus | ISO 178 | 15000 | Mpa | |
| Tensile strain | Break | ISO 527-2 | 2.8 | % |
| tensile strength | Break | ISO 527-2 | 250 | Mpa |
| Tensile modulus | ISO 527-2 | 16500 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | TD:-40to23°C | ISO 11359-2 | 5.5E-05 | cm/cm/°C |
| Melting temperature | ISO 11357-3 | 260 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 236 | °C |
| Linear coefficient of thermal expansion | TD:-- | ISO 11359-2 | 5.5E-05 | cm/cm/°C |
| MD:-40to23°C | ISO 11359-2 | 1.7E-05 | cm/cm/°C | |
| MD:-- | ISO 11359-2 | 1.4E-05 | cm/cm/°C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | MD | ISO 294-4 | 0.20 | % |
| TD | ISO 294-4 | 0.40 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | IEC 60112 | PLC 0 | ||
| Volume resistivity | IEC 60093 | 1E+15 | ohms·cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.