PA6 1013G43 MITSUBISHI ENGINEERING JAPAN
176
Form:Granules | Grade:Injection grade
Properties:
high strengthHigh rigidityGlass fiber reinforcement
Typical Applications:
Automotive sectorElectronic and Electrical Applications
Product Description
Certificates(0)
Datasheet
Alternative(5)
Product Description
| Typical Applications: | Automotive sector | Electronic and Electrical Applications |
| Properties: | high strength | High rigidity | Glass fiber reinforcement |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 1/2寸 | D256 | 10(21) | Kgf.cm/cm |
| 1/2寸 | D256 | 98(210) | J/m | |
| Bending modulus | D790 | 80000(45000) | ||
| D790 | 7.84(4.41) | GPa | ||
| bending strength | D790 | 2500(1380) | Kgf/cm | |
| D790 | 250(135) | Mpa | ||
| Stretching length | D638 | 4(5) | % | |
| tensile strength | D638 | 1650(1040) | Kgf/cm | |
| D638 | 160(100) | Mpa | ||
| Friction coefficient | D1894 | 0.35 | ||
| Taber wear resistance | D1044 | 14 | mg/1000cy | |
| Impact strength of cantilever beam gap | 1/8寸 | D256 | 14(30) | Kgf.cm/cm |
| 1/8寸 | D256 | 140(290) | J/m | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL 94 | HB | ||
| Linear coefficient of thermal expansion | D696 | 3 | ||
| Hot deformation temperature | HDT | D648 | 220 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | 0.2/0.4 | MD% | ||
| Rockwell hardness | D785 | 121(113) | R | |
| Water absorption rate | D570 | 2.5 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Arc resistance | ℃ | 130-140 | S | |
| Dielectric loss | Tangent | D150 | 0.02(0.1) | |
| Dielectric constant | D150 | 35-53(88) | Pf/m | |
| Dielectric strength | D149 | 15(15) | MV/m |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.