Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | ASTM D955 | 0.10 % |
Water absorption rate | | ASTM D570 | 0.30 % |
density | | ASTM D792 | 1.43 g/cm³ |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-0 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ASTM D638 | 24100 MPa |
tensile strength | | ASTM D638 | 179 MPa |
elongation | Break | ASTM D638 | 1.0 % |
Flexural modulus | | ASTM D790 | 17200 MPa |
bending strength | | ASTM D790 | 241 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | 53 J/m |
Suspended wall beam without notch impact strength | | ASTM D4812 | 430 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | ASTM D257 | 1E+06 ohms |
Volume resistivity | | ASTM D257 | 1E+03 ohms·cm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTM D648 | 218 °C |
Heat distortion temperature | | ASTM D648 | 213 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.