PA12 LV-3H EMS-CHEMIE USA
50
Form:Granules | Grade:Injection grade
Properties:
Weather resistanceChemical resistancewear resistantdimensional stability Low temperature impact reGas barrierGlass fiber reinforced
Typical Applications:
Automotive sectorShellelectrical machineryElectrical fieldElectronic fieldchipmachineMechanical components
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive sector | Shell | electrical machinery | Electrical field | Electronic field | chip | machine | Mechanical components |
| Properties: | Weather resistance | Chemical resistance | wear resistant | dimensional stability | Low temperature impact re | Gas barrier | Glass fiber reinforced |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | -30℃-30°C | ISO 179/1eU | 90 | kJ/m² |
| 23℃23°C | ISO 179/1eU | 90 | kJ/m² | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2 | 6500 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8 MPa,Unannealed264 psi, Unannealed | ISO 75-2/A | 160 | °C |
| 8.0 MPa,Unannealed1160 psi, Unannealed | ISO 75-2/C | 90 | °C | |
| Melting temperature | ISO 11357-3 | 178 | °C | |
| Linear coefficient of thermal expansion | MDFlow | ISO 11359-2 | 0.000020 | 1/℃ |
| TDTransverse | ISO 11359-2 | 0.00015 | 1/℃ | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.22 | g/cm³ | |
| Shrinkage rate | TDAcross Flow | ISO 294-4 | 0.8 | % |
| MDFlow | ISO 294-4 | 0.1 | % | |
| Water absorption rate | Saturation,23℃Saturation, 73°F | ISO 62 | 1.1 | % |
| Equilibrium,23℃,50% RHEquilibrium, 73°F, 50% RH | ISO 62 | 0.6 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface Resistance | IEC 60093 | -- | ohms | |
| Volume resistivity | IEC 60093 | -- | ohms·cm | |
| Dielectric strength | IEC 60243-1 | -- | KV/mm | |
| Compared to the leakage tracking index, the comparative tracking index | IEC 60112 | -- | V | |
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL 94 | HB |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.