Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | ASTM D-955 | 0.4 % |
density | | ASTMD792 | 1.04 g/cm³ |
melt mass-flow rate | | ASTMD1238 | 2.3 g/10min |
melt mass-flow rate | | ASTMD1238 | 23 g/10min |
Shrinkage rate | | ASTMD955 | <0.40 % |
Water absorption rate | | ASTMD570 | <0.30 % |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | | ASTMD785 | 119 |
processability | Test Condition | Test Method | Test Result |
---|
rti | | UL-746B | 60 °C |
flammability | Test Condition | Test Method | Test Result |
---|
FlameRating | | UL94 | HB |
Basic performance | Test Condition | Test Method | Test Result |
---|
density | | ASTM D-792 | 1.04 |
Water absorption rate | | ASTM D-570 | 0.3 wt% |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile strength at fracture point | | ASTM D-638 | 5400 psi |
elongation at break | | ASTM D-638 | 20 % |
Flexural Strength | | ASTM D-790 | 800 kg/cm |
Flexural Strength | | ASTM D-790 | 11400 psi |
Flexural coefficient | | ASTM D-790 | 30000 kg/cm |
Flexural coefficient | | ASTM D-790 | 420000 psi |
Rockwell hardness | | | 119 |
IZOD notch impact strength | | ASTM D-256 | 13 (2.4) kg.cm/cm(ft.1b/in) |
IZOD notch impact strength | | ASTM D-256 | 16 (2.9) kg.cm/cm(ft.1b/in) |
Tensile strength at the point of surrender | | ASTM D-638 | 480 kg/cm |
Tensile strength at the point of surrender | | ASTM D-638 | 6800 psi |
Tensile strength at fracture point | | ASTM D-638 | 380 kg/cm |
Tensile strength 2 | | ASTMD638 | 37.2 Mpa |
elongation | | ASTMD638 | 20 % |
Flexural modulus | | ASTMD790 | 2900 Mpa |
bending strength | | ASTMD790 | 78.6 Mpa |
tensile strength | | ASTMD638 | 46.9 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTMD256 | 160 J/m |
Impact strength of cantilever beam gap | | ASTMD256 | 150 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
arc resistance | | UL-746A | 15 Arcs |
Arc generation rate | | UL-746A | 0 in/min |
High arc combustion index (HAI) | | UL746 | 15.0 |
High voltage arc ignition resistance index | | UL746 | 0.00 mm/min |
Hot-wireIgnition | | UL746 | 15 sec |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ASTM D-648 | 89 (192) ℃(F) |
vicat | | ASTM D-1525 | 104 °C |
UL flame retardant rating | | UL94 | HB |
Resistance to hot wire combustion | | UL-746A | 15 Sece |
RTI Imp | | UL746 | 60.0 °C |
RTI Str | | UL746 | 60.0 °C |
| | ASTMD648 | 83.0 °C |
vicat | | ASTMD15254 | 104 °C |
RTI Elec | | UL746 | 60.0 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.