LCP Generic LCP - GlassMineral Generic
Properties:
Filler glass mineral
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass mineral |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179 | 3.6to20 | kJ/m² |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | 23°C | ASTM D790 | 11500to13000 | MPa |
| 23°C | ISO 178 | 10600to14100 | MPa | |
| bending strength | 23°C | ASTM D790 | 130to181 | MPa |
| 23°C | ISO 178 | 130to180 | MPa | |
| Tensile modulus | 23°C | ISO 527-2 | 11900to14200 | MPa |
| tensile strength | Break,23°C | ISO 527-2 | 110to131 | MPa |
| 23°C | ASTM D638 | 110to142 | MPa | |
| elongation | Break,23°C | ASTM D638 | 1.5to1.6 | % |
| Break,23°C | ISO 527-2 | 1.0to3.0 | % | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 270to335 | °C |
| 1.8MPa,Unannealed | ASTM D648 | 230to270 | °C | |
| 1.8MPa,Unannealed | ISO 75-2/A | 235to261 | °C | |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 6.0E-6到9.2E-6 | cm/cm/°C |
| TD | ISO 11359-2 | 4.3E-5到4.4E-5 | cm/cm/°C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | -- | ASTM D792 | 1.66to1.68 | g/cm³ |
| 23°C | ISO 1183 | 1.65to1.77 | g/cm³ | |
| Shrinkage rate | MD:23°C | ASTM D955 | 0.010to0.20 | % |
| 23°C | ISO 294-4 | 0.0to0.51 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | 23°C | IEC 60093 | 1.0E+15到2.1E+16 | ohms·cm |
| Dielectric strength | 23°C | IEC 60243-1 | 21to48 | kV/mm |
| Dielectric constant | 23°C | IEC 60250 | 3.70to4.35 | |
| Dissipation factor | 23°C | IEC 60250 | 9.7E-3到0.030 | |
| Arc resistance | ASTM D495 | 181to183 | sec | |
| Compared to the anti leakage trace index | IEC 60112 | PLC 3 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.