Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ISO 1183 | 1200 | |
melt mass-flow rate | ISO 1133 | 12 | |
Water absorption rate | ISO 62 | 0.23 | |
Shrinkage rate | ASTM D955 | 0.5-0.7 % |
optical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
refractive index | ASTM D542 | 1.585 | |
transmittance | ISO 13468-1 | 85-89 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tension modulus | ISO 527 | 2000 Mpa | |
bending strength | ISO 178 | 90 Mpa | |
Flexural modulus | ISO 178 | 2300 Mpa | |
Charpy impact strength | ISO 179 | 80 KJ/m2 | |
Rockwell hardness | ISO 2039-2 | 120 R | |
ISO 2039-2 | 50 M | ||
tensile strength | ISO 527 | 65 Mpa | |
Tensile strength | ISO 527 | 65 Mpa | |
Fracture rate | ISO 527 | 95 % |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Flame retardancy | UL94 | HB | |
ISO 75-1 | 125 ℃ | ||
ASTM D696 | 6.5 | ||
Flame retardancy | UL94 | V-2 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.