PEEK LUVOCOM® 1105-8000 LEHVOSS Group
Properties:
Filler carbon fiber reinforced material
Typical Applications:
Applications in the automotive field bearings textile applications gears pump components engineering parts medical nursing supplies bushings aerospace applications
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Applications in the automotive field | bearings | textile applications | gears | pump components | engineering parts | medical | nursing supplies | bushings | aerospace applications |
| Properties: | Filler | carbon fiber reinforced material |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 35 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL 94 | V-0 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2 | 15000 | MPa | |
| tensile strength | Break | ISO 527-2 | 170 | MPa |
| Tensile strain | Yield | ISO 527-2 | 1.5 | % |
| Bending modulus | ISO 178 | 13000 | MPa | |
| bending strength | ISO 178 | 235 | MPa | |
| Bending strain | ISO 178 | 2.0 | % | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 260 | °C |
| Continuous use temperature | UL 746B | 250 | °C | |
| Maximum operating temperature | ShortTerm | 280 | °C | |
| Vicat softening temperature | ISO 306/A | 295 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.56 | g/cm³ | |
| melt mass-flow rate | 380°C/10.0kg | ISO 1133 | 20 | g/10min |
| Shrinkage rate | DIN 16901 | 0.30to0.60 | % | |
| Water absorption rate | 23°C,24hr | <0.10 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | >1.0E+9 | ohms | |
| insulation resistance | IEC 60167 | >1.0E+9 | ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.