PC 2200R SABIC INNOVATIVE SAUDI
382
Form:Granules | Grade:Injection grade
Properties:
High impact resistanceHigh temperature resistantransparentHigh mobility
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | High impact resistance | High temperature resistan | transparent | High mobility |
Certificates
No Data...
Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Refractive index | ISO 179/leA | 1.586 | ||
| transmissivity | 2540 μm | ASTM D1003 | 88.0 to 90.0 | % |
| turbidity | 2540 μm | ASTM D1003 | < 0.80 | % |
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Suspended wall beam without notch impact strength | 23°C | ASTM D4812 | 无断裂 | |
| -30°C8 | ISO 180/1U | 无断裂 | ||
| Dart impact | 23°C, Energy at Peak | ASTM D3763 | 55.0 | J |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.5 mm | UL 94 | V-2 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | --3 | ASTM D638 | 2350 | Mpa |
| -- | ISO 527-2/1 | 2350 | Mpa | |
| tensile strength | Yield4 | ASTM D638 | 63.0 | Mpa |
| Yield | ISO 527-2/50 | 63.0 | Mpa | |
| elongation | Yield4 | ASTM D638 | 6.0 | % |
| Yield | ISO 527-2/50 | 6.0 | % | |
| Break4 | ASTM D638 | > 70 | % | |
| Break | ISO 527-2/50 | > 70 | % | |
| Bending modulus | 50.0 mm Span5 | ASTM D790 | 2300 | Mpa |
| --6 | ISO 178 | 2300 | Mpa | |
| bending strength | --6,7 | ISO 178 | 90.0 | Mpa |
| Yield, 50.0 mm Span5 | ASTM D790 | 90.0 | Mpa | |
| injection | Test Condition | Test Method | Test Result | Test Unit |
| drying temperature | 120 | °C | ||
| drying time | 2.0 to 4.0 | hr | ||
| Suggested maximum moisture content | 0.020 | % | ||
| Hopper temperature | 60 to 80 | °C | ||
| Temperature at the rear of the barrel | 260 to 280 | °C | ||
| Temperature in the middle of the barrel | 270 to 290 | °C | ||
| Temperature at the front of the material cylinder | 280 to 300 | °C | ||
| Spray nozzle temperature | 270 to 290 | °C | ||
| Processing (melt) temperature | 280 to 300 | °C | ||
| Mold temperature | 80 to 100 | °C | ||
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45 MPa, Unannealed, 3.20 mm | ASTM D648 | 133 | °C |
| 0.45 MPa, Unannealed, 4.00 mm, 64.0 mm Span9 | ISO 75-2/Bf | 133 | °C | |
| 1.8 MPa, Unannealed, 3.20 mm | ASTM D648 | 122 | °C | |
| 1.8 MPa, Unannealed, 4.00 mm, 64.0 mm Span9 | ISO 75-2/Af | 122 | °C | |
| Vicat softening temperature | ISO 306/B50 | 140 | °C | |
| Ball Pressure Test | 123 to 127°C | IEC 60695-10-2 | 通过 | |
| Linear coefficient of thermal expansion | -40 to 95°C,Flow | ASTM E831 | 7.0E-5 | cm/cm/°C |
| 23 to 80°C,Flow | ISO 11359-2 | 7.0E-5 | cm/cm/°C | |
| thermal conductivity | ASTM C177 | 0.20 | W/m/K | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | 300°C/1.2 kg | ASTM D1238 | 22 | g/10 min |
| Melt Volume Flow Rate (MVR) | 300°C/1.2 kg | ISO 1133 | 21.0 | cm3/10min |
| Shrinkage rate | --2,Flow | Internal Method | 0.50 - 0.70 | % |
| 3.20 mm,Flow | Internal Method | 0.50 - 0.70 | % | |
| Water absorption rate | Saturation, 23°C | ISO 62 | 0.35 | % |
| Equilibrium, 23°C | ASTM D570 | 0.35 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | ASTM D257 | > 1.0E+15 | ohms·cm | |
| Dielectric strength | 1.60 mm | ASTM D149 | 27 | KV/mm |
| Dielectric constant | 60 Hz | ASTM D150 | 3.00 | |
| 1 MHz | ASTM D150 | 3.00 | ||
| Dissipation factor | 60 Hz | ASTM D150 | 1.0E-3 | |
| 1 MHz | ASTM D150 | 0.010 | ||
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Scale | ASTM D785 | 120 | |
| R -Sale | ISO 2039-2 | 120 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.