LCP L304G35 TORAY JAPAN
169
Form:Granules | Grade:Injection grade
Properties:
enhanceGlass fiber reinforcedHigh mobilityFiller: Glass fiber reinf35%Filler by weight
Typical Applications:
Electrical componentsElectrical appliances
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Electrical components | Electrical appliances |
| Properties: | enhance | Glass fiber reinforced | High mobility | Filler: Glass fiber reinf | 35% | Filler by weight |
Certificates

Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | ASTM D256 | 75 | J/m | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.200mm | UL 94 | V-0 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | ASTM D790 | 160 | Mpa | |
| Bending modulus | ASTM D790 | 13000 | Mpa | |
| elongation | Break | ASTM D638 | 3.0 | % |
| tensile strength | ASTM D638 | 135 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | MD | ASTM D696 | 6.0E-6to2.5E-5 | cm/cm/°C |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 270 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 23°C,24hr | ASTM D570 | 0.010 | % |
| Shrinkage rate | MD:1.00mm3 | Internal Method | -0.030 | % |
| TD:1.00mm2 | Internal Method | 0.83 | % | |
| density | ASTM D792 | 1.65 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric constant | ASTM D150 | 4.10 | ||
| Dielectric strength | ASTM D149 | 50 | KV/mm | |
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 3 | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Scale | ASTM D785 | 105 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.