PA66 VENYL ZG307 - 7761 AD MAJORIS FRANCE
0
- Properties:Filler glass fiber reinforced material 30% filler by weight
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of simply supported beam without notch | ISO 179 | 80 kJ/m² | |
| Charpy Notched Impact Strength | ISO 179 | 11 kJ/m² |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| UL flame retardant rating | 1.6mm | UL 94 | HB |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| bending strength | ISO 178 | 235 MPa | |
| Bending modulus | ISO 178 | 8300 MPa | |
| Tensile strain | Break | ISO 527-2 | 3.0 % |
| Yield | ISO 527-2 | 3.0 % | |
| tensile strength | Break | ISO 527-2 | 185 MPa |
| Tensile modulus | ISO 527-2 | 9800 MPa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Linear coefficient of thermal expansion | MD | DIN 52328 | 3E-05 cm/cm/°C |
| Melting temperature | ISO 3146 | 242 °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 230 °C |
| 0.45MPa,Unannealed | ISO 75-2/B | 235 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Water absorption rate | 23°C,24hr | ISO 62 | 0.95 % |
| Shrinkage rate | 0.50to0.70 % | ||
| density | ISO 1183 | 1.37 g/cm³ |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Compared to the anti leakage trace index | SolutionA | IEC 60112 | PLC 1 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.