Share
Add to Compare

PBT T 7141 901510 LANXESS GERMANY

11

Form:Granules

Product Description
Certificates(0)
Datasheet

Product Description

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Suspended wall beam without notch impact strength23°CISO 180/1U35kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
Hot filament ignition temperature3.0mmIEC 60695-2-13775°C
Hot filament ignition temperature1.5mmIEC 60695-2-13775°C
Hot filament ignition temperature0.8mmIEC 60695-2-13775°C
Burning wire flammability index3.0mmIEC 60695-2-12750°C
Burning wire flammability index1.5mmIEC 60695-2-12750°C
Burning wire flammability index0.8mmIEC 60695-2-12750°C
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Bending strain23°C2.0%
bending strength23°CISO 178175Mpa
Bending modulus23°CISO 178/A11000Mpa
Tensile strainBreak,23°CISO 527-2/51.6%
tensile strengthBreak,23°CISO 527-2/5125Mpa
Tensile modulus23°CISO 527-2/112000Mpa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature0.45MPa,UnannealedISO 75-2/B250°C
Linear coefficient of thermal expansionTD:23to55°CISO 11359-25E-05cm/cm/°C
Linear coefficient of thermal expansionMD:23to55°CISO 11359-22E-05cm/cm/°C
Melting temperatureISO 11357-3260°C
Vicat softening temperatureISO 306/B120220°C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A205°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Shrinkage rateMD:120°C,2hr,2.00mm3ISO 294-40.10%
Shrinkage rateMD:280°C,2.00mm2ISO 294-40.20%
Shrinkage rateTD:120°C,2hr,2.00mm3ISO 294-40.10%
Shrinkage rateTD:280°C,2.00mm2ISO 294-40.70%
Melt Volume Flow Rate (MVR)280°C/2.16kgISO 113325.0cm3/10min
Apparent densityISO 600.90g/cm³
Supplementary InformationTest ConditionTest MethodTest ResultTest Unit
ISO ShortcutISO 7792PET+PBT.GHMR.07-120.(GF+MD)40
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.