Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | ISO 294-4 | 2.1 % |
Shrinkage rate | | ISO 294-4 | 2.1 % |
Water absorption rate | | ISO 62 | 1.7 % |
flammability | Test Condition | Test Method | Test Result |
---|
Hot filament ignition temperature | | IEC 60695-2-13 | 960 °C |
Hot filament ignition temperature | | IEC 60695-2-13 | 960 °C |
Hot filament ignition temperature | | IEC 60695-2-13 | 750 °C |
UL flame retardant rating | | UL 94 | V-2 |
Burning wire flammability index | | IEC 60695-2-12 | 960 °C |
Burning wire flammability index | | IEC 60695-2-12 | 960 °C |
Burning wire flammability index | | IEC 60695-2-12 | 960 °C |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO 527-2/1 | 3000 Mpa |
tensile strength | | ISO 527-2/50 | 84.0 Mpa |
Tensile strain | | ISO 527-2 | 4.4 % |
Tensile strain | | ISO 527-2 | 30 % |
Flexural modulus | | ISO 178 | 2900 Mpa |
bending strength | | ISO 178 | 94.0 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of simply supported beam without notch | | ISO 179 | NoBreak |
Impact strength of simply supported beam without notch | | ISO 179 | NoBreak |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Volume resistivity | | IEC 60093 | 10 ohms·cm |
dielectric strength | | IEC 60243-1 | 18 KV/mm |
Compared to the Leakage Tracking Index (CTI) | | IEC 60112 | V |
Thermal performance | Test Condition | Test Method | Test Result |
---|
melting temperature | | ISO 11357-3 | 260 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.