physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ASTM D792 | 1.20 g/cm³ |
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
Shore hardness | ASTM D2240 | 81 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ASTM D638 | 2240 MPa | |
tensile strength | Yield | ASTM D638 | 46.2 MPa |
Flexural modulus | ASTM D790 | 2280 MPa | |
bending strength | ASTM D790 | 68.3 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of cantilever beam gap | ASTM D256A | 120 J/m | |
Dart impact | ASTM D4226 | 49.4 J/cm | |
ASTM D4226 | >178 J/cm |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ASTM D648 | 84.4 °C | |
ASTM D648 | 75.6 °C | ||
Linear coefficient of thermal expansion | ASTM D696 | 8.5E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.