PA6 Staramide BG2ST43 EUROSTAR FRANCE
Properties:
Filler glass fiber reinforced material
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass fiber reinforced material |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | -20°C | ISO 180/1A | 14 | kJ/m² |
| 23°C | ISO 180/1A | 20 | kJ/m² | |
| -40°C | ISO 180/1A | 13 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.75mm | UL 94 | HB | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile strain | Break | ISO 527-2/5 | 10 | % |
| tensile strength | Break | ISO 527-2/5 | 75.0 | MPa |
| Tensile modulus | ISO 527-2/1 | 4200 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | -- | ISO 306/B50 | 170 | °C |
| -- | ISO 306/A50 | 185 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed,100mmSpan | ISO 75-2/Ae | 145 | °C |
| 0.45MPa,Unannealed,100mmSpan | ISO 75-2/Be | 180 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | MD | Internal Method | 0.95to1.4 | % |
| density | ISO 1183 | 1.17 | g/cm³ | |
| Water absorption rate | Saturation,23°C | ISO 62 | 6.0 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | IEC 60112 | PLC 1 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.