PA610 LNP™ LUBRICOMP™ QL4040 NT92
123
- Properties:Thermal stabilityConductiveGlass fiber reinforced
- Usages:Electronic and Electrical ApplicationsFitness equipment
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | ASTM D955 | 1.0-3.0 % | |
ASTM D955 | 1.0-3.0 % | ||
Water absorption rate | ASTM D570 | 0.26 % | |
ISO 62 | 0.37 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ASTM D638 | 2430 Mpa | |
ISO 527-2/1 | 2490 Mpa | ||
tensile strength | ASTM D638 | 53.0 Mpa | |
ISO 527-2/5 | 53.0 Mpa | ||
ASTM D638 | 53.0 Mpa | ||
ISO 527-2/5 | 52.0 Mpa | ||
elongation | ASTM D638 | 14 % | |
Tensile strain | ISO 527-2/5 | 11 % | |
elongation | ASTM D638 | 16 % | |
Tensile strain | ISO 527-2/5 | 11 % | |
Flexural modulus | ASTM D790 | 1710 Mpa | |
ISO 178 | 2320 Mpa | ||
bending strength | ISO 178 | 50.0 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of cantilever beam gap | ISO 180/1A | 4.2 kJ/m² | |
Suspended wall beam without notch impact strength | ISO 180/1U | 32 kJ/m² | |
Dart impact | ASTM D3763 | 3.20 J | |
Multi axis Instrumented Impact Energy | ISO 6603-2 | 1.40 J |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ASTM D648 | 181 °C | |
ISO 75-2/Bf | 170 °C | ||
ASTM D648 | 56.0 °C | ||
ISO 75-2/Af | 60.0 °C | ||
Linear coefficient of thermal expansion | ASTM D696 | 1.1E-04 cm/cm/°C | |
ASTM D696 | 1.1E-04 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.
Contact Us
Get App
Top