LCP A430 JAPAN POLYPLASTIC
176
Form:Granules | Grade:Injection grade
Properties:
Electrical performancewear resistantLubricityHalogen-freeFlame retardantGood electrical performanFlame retardantlubricationGood wear resistance
Typical Applications:
Electrical applicationsHome appliance components
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Electrical applications | Home appliance components |
| Properties: | Electrical performance | wear resistant | Lubricity | Halogen-free | Flame retardant | Good electrical performan | Flame retardant | lubrication | Good wear resistance |
Certificates

Technical Data Sheet
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| density | ISO 1183 | 1500 | kg/m | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | 23℃ | ISO 180/1A | 35.0 | KJ/m |
| Suspended wall beam without notch impact strength | 23℃ | ISO 180/1U | 67.0 | KJ/m |
| Rockwell hardness | ISO 2039-2 | 55 | M Scale | |
| Tensile modulus | ISO 527-1 | 7000 | Mpa | |
| tensile strength | ISO 527-1 | 160 | Mpa | |
| elongation | Break | ISO 527-1 | 6.2 | % |
| Bending modulus | 23℃ | ISO 178 | 7000 | Mpa |
| bending strength | 23℃ | ISO 178 | 125 | Mpa |
| Charpy Notched Impact Strength | 23℃ | ISO 179/1eA | 28.0 | KJ/m |
| Impact strength of simply supported beam without notch | 23℃ | ISO 179/1eU | 86.0 | KJ/m |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa | ISO 75-1 | 227 | °C |
| 1.80MPa | ISO 75-1 | 165 | °C | |
| 8.00MPa | ISO 75-1 | 89.0 | °C | |
| Vicat softening temperature | 50℃/h 50N | ISO 306 | 138 | °C |
| Linear coefficient of thermal expansion | parallel | ISO 11359-1 | 1E-06 | cm/cm℃ |
| normal | ISO 11359-1 | 0.000046 | cm/cm℃ | |
| Combustibility | UL 94 | V-0 | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | normal | ISO 2577 | 0.0 | % |
| parallel | ISO 2577 | 0.70 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | 1E+15 | ohms | |
| Volume resistivity | IEC 60093 | 1E+13 | ohm.m | |
| Relative permittivity | 100Hz | IEC 60250 | 3.30 | |
| 1000Hz | IEC 60250 | 2.70 | ||
| Dielectric loss | 100Hz | IEC 60250 | 0.030 | |
| 1000Hz | IEC 60250 | 0.016 | ||
| Compared to the Leakage Traceability Index (CTI) | IEC 60112 | 225 | ||
| Dielectric strength | IEC 60243-1 | 36 | KV/mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.