PA6 XG-FKGS6 DSM Additive Manufacturing
Properties:
Filler glass fiber reinforced material 30% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass fiber reinforced material | 30% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 8.0 | kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 50 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Burning wire flammability index | 0.8mm | IEC 60695-2-12 | 960 | °C |
| UL flame retardant rating | 1.6mm | IEC 60695-11-10,-20 | V-0 | |
| 0.8mm | IEC 60695-11-10,-20 | V-0 | ||
| Hot filament ignition temperature | 1.6mm | IEC 60695-2-13 | 775 | °C |
| 1.0mm | IEC 60695-2-13 | 775 | °C | |
| Burning wire flammability index | 1.6mm | IEC 60695-2-12 | 960 | °C |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile strain | Break | ISO 527-2 | 2.0 | % |
| tensile strength | Break | ISO 527-2 | 135 | MPa |
| Tensile modulus | ISO 527-2 | 11500 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 205 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 1.7 | % |
| Shrinkage rate | MD | ISO 294-4 | 0.20 | % |
| TD | ISO 294-4 | 0.60 | % | |
| density | ISO 1183 | 1.47 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | IEC 60112 | V |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.