LCP E130I VC3052 CELANESE USA
31
Form:Granules | Grade:Extrusion grade
Properties:
heat-resistingFlame retardantenhance
Typical Applications:
Household appliancesHousehold appliances
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Household appliances | Household appliances |
| Properties: | heat-resisting | Flame retardant | enhance |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 31 | kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 43 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL 94 | V-0 | ||
| Extreme Oxygen Index | ISO 4589-2 | 45 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Fracture bending strain | ISO 178 | 2.2 | % | |
| CompressiveStress | 1%Strain | ISO 604 | 93.0 | Mpa |
| Compressive modulus | ISO 604 | 14000 | Mpa | |
| bending strength | 23°C | ISO 178 | 220 | Mpa |
| Bending modulus | 23°C | ISO 178 | 13500 | Mpa |
| Tensile modulus | ISO 527-2/1A/1 | 15000 | Mpa | |
| tensile strength | Break | ISO 527-2/1A/5 | 150 | Mpa |
| Tensile strain | Break | ISO 527-2/1A/5 | 1.6 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | TD | ISO 11359-2 | 2E-05 | cm/cm/°C |
| MD | ISO 11359-2 | 7E-06 | cm/cm/°C | |
| Melting temperature | ISO 11357-3 | 335 | °C | |
| Vicat softening temperature | ISO 306/B50 | 195 | °C | |
| Hot deformation temperature | 8.0MPa,Unannealed | ISO 75-2/C | 216 | °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 276 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | TD | ISO 294-4 | 0.40 | % |
| MD | ISO 294-4 | 0.10 | % | |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.030 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | IEC 60112 | V | ||
| Arc resistance | Internal Method | 140 | sec | |
| Dissipation factor | 2.05GHz | Internal Method | 6E-03 | |
| 1MHz | IEC 60250 | 0.025 | ||
| 100Hz | IEC 60250 | 0.010 | ||
| Dielectric strength | IEC 60243-1 | 32 | KV/mm | |
| Volume resistivity | IEC 60093 | 1E+15 | ohms·cm | |
| Surface resistivity | IEC 60093 | 1E+14 | ohms | |
| Relative permittivity | 2.05GHz | Internal Method | 4.23 | |
| 1MHz | IEC 60250 | 3.30 | ||
| 100Hz | IEC 60250 | 4.00 | ||
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | M-Scale | ISO 2039-2 | 71 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.