PC 4610-10 STYRON TAIWAN
13
Form:Granules | Grade:Injection grade
Properties:
transparentMiddle flow Medium liquiditytransparent Medium liquiditytransparent
Product Description
Certificates(0)
Datasheet
Alternative Model(1)
Product Description
| Properties: | transparent | Middle flow | Medium liquidity | transparent | Medium liquidity | transparent |
Certificates
No Data...
Technical Data Sheet
| Other performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Glow wire combustion index (GWFI) | 2.0mm | IEC 695-2-1 | 960 | °C |
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | 300℃/1.2kg | ASTM D-1238 | 10 | g/10min |
| density | ASTM D-792 | 1200 | kg/m | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | ASTM D-790 | 100 | Mpa | |
| Tensile modulus | ASTM D-638 | 2240 | Mpa | |
| tensile strength | Yield | ASTM D-638 | 61 | Mpa |
| Impact strength of cantilever beam gap | 23℃ | ASTM D-256 | 900 | J/m |
| tensile strength | Break | ASTM D-638 | 66 | Mpa |
| Suspended wall beam without notch impact strength | 23℃ | ASTM D-256 | 未破裂 | |
| elongation at yield | ASTM D-638 | 6 | % | |
| Bending modulus | ASTM D-790 | 2400 | Mpa | |
| elongation | Break | ASTM D-638 | 120 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | Unannealed@1.82MPa | ASTM D-648 | 127 | °C |
| Annealed@1.82MPa | ASTM D-648 | 140 | °C | |
| Annealed@0.45MPa | ASTM D-648 | 144 | °C | |
| Shrinkage rate | 50℃/hr,50n重 | ASTM D-1525 | 154 | °C |
| Ball indentation temperature | IEC 598-1 | >125 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.6mm | UL 94 | V-2 | |
| 3.2mm | UL 94 | V-0 | ||
| Shrinkage rate | ASTM D-955 | 0.005-0.007 | mm/mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.