Technical Data Sheet
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | 1.50300mm | UL 94 | HB |
optical performance | Test Condition | Test Method | Test Result |
---|
Reflectance-Initial | | ASTME1331 | 90 % |
Physical properties | Test Condition | Test Method | Test Result |
---|
density | | ASTMD792 | 1.60 g/cm³ |
melt mass-flow rate | 300°C/2.16kg | ASTMD1238 | 60 g/10min |
flow | | ASTM D955 | 0.41to0.50 % |
lateral flow | | ASTM D955 | 0.61to0.74 % |
Vertical flow direction | | ISO 2577 | 0.61to0.74 % |
Flow direction: | 流动方向 | ISO 2577 | 0.41to0.50 % |
mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile modulus | | ASTM D638 | 5600 MPa |
yield | | ASTM D638 | 62.0 MPa |
yield | | ISO 527-2/5 | 62.0 MPa |
fracture | | ASTM D638 | 61.0 MPa |
elongation | Break | ASTM D638 | 1.5 % |
impact performance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 2.0 kJ/m² |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.