PA66 54G35HSL DUPONT USA
39
Form:Granules | Grade:Flame retardant grade
Properties:
High temperature resistanHigh resistanceGlass fiber reinforcedHigh rigiditywear resistantFiller: Glass fiber reinf35%Filler by weight
Typical Applications:
Electrical appliancesHousehold appliancesAutomotive interior parts
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electrical appliances | Household appliances | Automotive interior parts |
| Properties: | High temperature resistan | High resistance | Glass fiber reinforced | High rigidity | wear resistant | Filler: Glass fiber reinf | 35% | Filler by weight |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 82 | kJ/m² |
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 11 | kJ/m² |
| Tensile modulus | 23°C | ISO 527-2 | 10500 | Mpa |
| Elongation at Break | 23°C | ISO 527-2 | 2.70 | % |
| tensile strength | 23°C | ISO 527-2 | 185 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | TD | ISO 11359-2 | 6E-05 | cm/cm/°C |
| MD | ISO 11359-2 | 2E-05 | cm/cm/°C | |
| Vicat softening temperature | Melting Temperature | ISO 11357-3 | 300 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | TD2.0mm | ISO 294-4 | 0.50 | % |
| MD2.0mm | ISO 294-4 | 0.20 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dissipation factor | 相对漏电起痕指数 | IEC 60112 | 575 | V |
| Dielectric strength | 0.250mm | IEC 60243-1 | 33 | KV/mm |
| Volume resistivity | IEC 60093 | >1.0E+15 | Ω.cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.