Polyolefin, Unspecified FRAGOM G/478 CROSSPOLIMERI ITALY
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| flammability | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Extreme Oxygen Index | ASTM D2863 | 35 | % | |
| HalogenContent | IEC 60754-1 | <0.200 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Yield | IEC 60811 | 12.5 | MPa |
| Tensile strain | Break | IEC 60811 | 200 | % |
| Break2 | >50 | % | ||
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| thermosetting | 250°C | IEC 60811 | 50 | % |
| Residual:250°C | IEC 60811 | 5.0 | % | |
| Temperature index | IEC 60811 | 290 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792 | 1.45 | g/cm³ | |
| melt mass-flow rate | 190°C/21.6kg | ASTM D1238 | 7.0 | g/10min |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | IEC 60093 | >1.0E+14 | ohms·cm | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Shore hardness | ShoreD | ASTM D2240 | 48 | |
| aging | Test Condition | Test Method | Test Result | Test Unit |
| Change rate of tensile strength in air | 135°C,168hr | IEC 60811 | -12 | % |
| Tensile stress change rate | 135°C,168hr,Break | IEC 60811 | 6.0 | % |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| Corrosion-pH | IEC 60754-2 | >4.40 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.