Share
Add to Compare

POM K500HS KOLON KOREA

94

Form:Granules | Grade:Injection grade

Typical Applications:
Thin walled components
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:Thin walled components

Certificates

No Data...

Technical Data Sheet

flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating0.8mmUL 94HB
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
tensile strength23°CASTM D63866.0Mpa
tensile strengthYield,23°CISO 527-267.0Mpa
elongationBreak,23°CASTM D63855%
Tensile strainBreak,23°CISO 527-230%
Bending modulus23°CASTM D7902900Mpa
Bending modulus23°CISO 1782950Mpa
bending strength23°CASTM D79098.0Mpa
bending strength23°CISO 17895.0Mpa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature0.45MPa,UnannealedASTM D648A158°C
Hot deformation temperature1.8MPa,UnannealedASTM D648A110°C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A100°C
Vicat softening temperatureASTM D1525162°C
Melting temperatureISO 11357-3173°C
Melting temperatureASTM D1525173°C
Linear coefficient of thermal expansionMDASTM D6961.3E-05cm/cm/°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
melt mass-flow rate190°C/2.16kgASTM D123814g/10min
melt mass-flow rate190°C/2.16kgISO 113315g/10min
Shrinkage rateMDASTM D9552.0%
Shrinkage rateTDISO 294-42.2%
Shrinkage rateMDISO 294-42.3%
Water absorption rate23°C,24hrISO 620.53%
Water absorption rateEquilibrium,23°C,60%RHASTM D5700.22%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Surface resistivityASTM D2571E+16ohms
Surface resistivityIEC 600931E+16ohms
Volume resistivityASTM D2571E+14ohms·cm
Volume resistivityIEC 600931E+14ohms·cm
Dielectric strengthASTM D14919KV/mm
Dielectric strengthIEC 60243-119KV/mm
Dielectric constantASTM D1503.70
Dissipation factor1MHzASTM D1506E-03
hardnessTest ConditionTest MethodTest ResultTest Unit
Rockwell hardnessM-ScaleASTM D78582
Rockwell hardnessM-ScaleISO 2039-296
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.